Packaged Roof Top and Split A/C Systems
- Constant Volume, VAV, VVT
- Unlimited by tonnage or refrigerant type
- All major brands
Chillers
- Water and Air Cooled
- Scroll, Reciprocating, and Hermetic Screw Compressors
- All refrigerants and all brands

Boilers
- Water and Low/Medium Pressure Steam
- Gas burners, oil burners, and “Dual Fuel” burners up to 200 horsepower, regardless of brand
- Combustion efficiency testing utilizing Bacharach Electronic analyzer instrumentation with printout of results
Pumps and Piping
- On-site repair/rebuild of water circulation pumps
- Gas/Fuel oil piping
- Threaded black iron up to 2 inch diameter pipe
- Copper piping with conventional joining such as soldering/brazing, and also with more recent means such as mechanical compression using the Rigid “Pro-Press”

Motor Control and Variable Frequency Drives (VFDs)
- Fractional to 100 HP VFDs, install, service/repair, and maintenance of most major brands